Configuring a port config profile, Configuring a port config profile -50 – Lucent Technologies 6000 User Manual

Page 94

Advertising
background image

3-50

MAX 6000/3000 Network Configuration Guide

Configuring WAN Access
Configuring Host/AIM6 and Host/Dual ports

For detailed information about each parameter, see the MAX Reference.

Configuring a Port Config profile

To configure an inverse multiplexing port, perform the following steps:

1

Open a Host/AIM6 > Port1 Menu > Port Config profile and set the Port Name parameter
to assign a name to the profile.

2

Set the Ans N# parameters to configure call routing.

3

Set the Dial, Answer, and Clear parameters appropriately for the codec.

4

Set the Dial Plan parameter to trunk group to specify that the digits following the first digit
constitute an ordinary telephone number, or set it to Extended to specify that the MAX
uses the extended dial plan.

5

Exit the profile and, at the exit prompt, select the exit and accept option.

Example of a Port Config profile

Host/AIM6

Port1 Menu

Directory

Port1

Port Name=Port1

Dial Plan=Trunk Grp

RS-366 Esc

Escape character the MAX uses during RS-366 ext2 dialing or during
X.21 ext2 dialing.

Early CD

When the MAX unit is to activate the Carrier Detect (CD) signal at the
AIM port. When the unit receives a signal indicating that a sender has
data to transmit, it activates the CD signal. If Early CD is set to its
default value of None, the unit activates the CD signal after the
completion of handshaking and an additional short delay.

DS0 Min Rst

When (daily or monthly) the MAX should reset accumulated DS0
minutes to 0 (zero). A DS0 minute is the online usage of a single
56-Kbps or 64-Kbps switched channel for one minute. You can also
set this parameter to specify that the MAX should disable the timer
altogether.

Max DS0 Mins

Maximum number of DS0 minutes a call can be online. Applies to
calls from the AIM port within the specified time period. When the
usage exceeds the specified maximum, the MAX cannot place any
more calls, and it takes any existing calls offline.

Max Call Mins

Maximum number of minutes a call can be online at the port,
regardless of bandwidth, before the MAX disconnects it. This
maximum limits the usage of switched channels, even if the MAX
combines these channels with nailed ones. Although the MAX
disconnects the switched channels when a call exceeds the value of
this parameter, the nailed channels remain connected.

Port Password

Password for incoming AIM or BONDING calls. Authentication is
used only if the calling unit has a password defined in the Call profile.