Advanced Setup Summary

976-0043-01-02

7–7

27A Push INV now to save
Settings

Push INV now to Save Settings

page 7–39

27B Push GEN to restore
settings

Push GEN to restore settings

page 7–40

27C Push GEN for factory
defaults

Push GEN for factory defaults

page 7–40

End Menu 27

END ADVANCED SETUP
MENU

Table 7-3 Advanced Setup Default Settings for the

Sine Wave Plus

Plus 5548 Models

Advanced Setup Menus

Sine Wave Plus

5548

See Page

Range/Display

Default
Settings

20 Silent Setup Menu

See

“20 Silent Setup Menu” on page 7–13

for details.

20A Refloat High Volts DC

32.2 to 67.8

56.8

page 7–15

20B Refloat Low Volts DC

32.2 to 67.8

50.0

page 7–15

20C Float Done Amps AC

00 to 40

10

page 7–15

20D Must Float Time Min

00 to 255

05

page 7–15

End Menu 20

21 Grid AC1 Usage Menu

See

“21 Grid (AC1) Usage Menu” on page 7–16

for details.

21A Grid Usage

SB BX

SB

page 7–17

21B Grid Usage Begin h:m

00:00 to 23:50

21:00

page 7–17

21C Grid Usage End h:m

00:00 to 23:50

21:00

page 7–18

End Menu 21

22 Battery Xfer (BX) Menu

See

“22 Battery Xfer (BX) Menu” on page 7–18

for details.

22A High Xfer (HBX) Vdc

32.2 to 67.8

54.0

page 7–19

22B Low Xfer (LBX) Vdc

32.2 to 67.8

46.0

page 7–19

End Menu 22

Table 7-2 Advanced Setup Default Settings for the

Sine Wave Plus

4024 and 4048 Models

Advanced Setup Menus

Sine Wave Plus

4024

Sine Wave Plus

4048

See Page

Range/Display

Default
Settings

Range/Display

Default
Settings