Battery Information

C–10

976-0043-01-02

Wiring Batteries in Parallel

Effect

Wiring the batteries in a parallel configuration increases the current of the
battery string. The voltage of the battery bank remains the same as an
individual battery. “Parallel” configurations extend the run times of the
AC loads by providing increased current for the inverter to draw from. In
a parallel configuration, all the negative battery terminals are connected
together and all the positive battery terminals are connected together.

Wiring example

Figure C-4

is an example only of how to wire batteries in a parallel

configuration. The

Sine Wave Plus

is not available in a 12-volt unit.

Figure C-2 12-volt Battery Wiring - “Series” Configuration

+

-

+

-

1 2 V

1 2 V

+

-

4 8 V IN V E R T E R

(T o ta l b a ttery c ap a c ity = 1 0 0 A h)

+

-

+

-

1 2 V

1 2 V

+

-

+

-

1 2 V

1 2 V

+

-

2 4 V IN V E R T E R

(T o ta l b a tte ry c a pa c ity = 1 0 0 A h )

S H U N T

S H U N T

D C D is c on ne c t
(e ithe r a c irc uit

bre ak e r or a

fu s e w ith a

dis c on ne c t)

D C D isc o nn ec t

(eith er a c ircu it

b rea k er o r a

fus e w ith a

d isc o nn ec t)

E a c h b a tte ry 's a m p -h o u r

ra tin g is 1 0 0 A h .

E a ch b a tte ry 's a m p -h o u r

ra t in g is 1 0 0 A h .

Figure C-3 Battery Wiring in Parallel (Example Only)

12-volt

Inverter

+

+

+

12-volt
Battery

12-volt

Battery

Battery Wiring configured in Parallel

SHUNT

DC Disconnect
(either a circuit

breaker or a

fuse with a

disconnect)

Total battery
capacity of 200 Ah

Each battery is rated
at 100 Ah.