17.2.2. Recording mode settings.

Each recording mode has predetermined settings for the following 5

parameters:

• Auto section setting - PLEXTALK can be set to automatically create

a new section, in a DAISY recording, after a specified amount of

time with no audio input, for example 2 seconds. Use the setting

"No setting" to create a continuous recording with no new sections.

• Time to auto stop recording when no sound - This is the time that

PLEXTALK will continue to record with no audio input. After this
time, recording stops automatically.

• Timing of start recording - Recording can be set to start either

when you press the Record Key or when input audio is detected.

• Background noise level of input sound - If you are recording in a

low noise environment, such as a studio, use the "low" setting. If

your recording environment is noisy, such as a conference or

lecture, use the "High" setting.

• Record speed setting - This setting can be used to choose between

normal speed recording and double speed recording. This can be

useful for dubbing from a double speed cassette.

The preset parameters for the 5 recording modes are as follows:

• Standard mode

Auto section setting: No setting

Time to auto stop recording when no sound: No setting

Timing of start recording: When push Record key

Background noise level of input sound: Normal (-28dB)

Record speed setting: Normal speed

• Music mode

Auto section setting: 2 seconds

Time to auto stop recording when no sound: 1 minute

Timing of start recording: When push Record key