Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

I/O Grouping

NOTE: The group that is assigned in each of the following I/O grouping commands (

X1^

) must be

1

,

2

,

3

,

4

, or

0

(not grouped).

Write input grouping

EX1^

1

X1^

2

...

X1^

n

I

}

Gri

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group number

assigned to an input position, starting
from input 1. n = the maximum
number of inputs for this model.

Example:

CrossPoint 450 Plus 3232

E

40...33I

}

See below.

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10 11 12

4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 2 not grouped

2 1 2 2 3 3 3 3

25 26 27 28 29 30 31 32

Input 32 in group 3

Input 1 - group 4,
input 2 - group 0 (ungrouped), ... input
31 - group 3,
input 32 - group 3.

Write output grouping

EX1^

1

X1^

2

...

X1^

n

O

}

Gro

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group number

assigned to an output position, starting
from output 1. n = the maximum
number of outputs for this model.

Read input grouping

E

I

}

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group number

assigned to an input position, starting
from input 1. n = the maximum
number of inputs for this model.

Example:

MAV Plus 2424

E

I

}

See below.

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08 09 10 11 12

1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 9 not grouped

Input 24 in group 3

Read output grouping

E

O

}

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group number

assigned to an output position, starting
from output 1. n = the maximum
number of outputs for this model.

NOTE:

X1^

= Group number (for I/O grouping) 1 through 4 groups (0 = no group)

CrossPoint and MAV Series Matrix Switchers • Programming Guide 102