background image

Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Names

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 109).

Write global preset name

EX(

,

X1!

NG

}

Nmg

X(

,

X1!]

Example:

E

1,Security 1NG

}

Nmg01,Security 1

]

Name global preset 1 “Security 1”.

Read global preset name

EX(

NG

}

X1!]

Example:

E

2NG

}

Security 2

]

Write room preset name

EX1)

*

X(

,

X1!

NP

}

Nmp

X1)

*

X(

,

X1!]

Example:

E

1*3,Podium_DVDNP

}

Nmp01*3,Podium_DVD

]

Name room 1, preset 3 “

Podium_

DVD

”.

Read room preset name

EX1)

,

X(

NP

}

X1!]

NOTES:

Do not use leading spaces in preset names.

If a preset is unassigned, the

X1!

displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset

X(

.

If a room preset is saved, but not yet named, the default name is Rm

X1)

Prst

X(

.

Write input name

EX!

,

X1!

NI

}

Nmi

X$

,

X1!]

Example:

E

1

,

Podium camNI

}

Nmi01

,

Podium cam

]

Name input 1 “Podium cam”.

Read input name

EX$

NI

}

X1!]

Write output name

EX@

,

X1!

NO

}

Nmo

X@

,

X1!]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1”.

Read output name

EX@

NO

}

X1!]

Front panel locks

NOTE: See

Setting the Front Panel Locks (Executive Modes)

on page 75 for more information on the Lock modes.

Lock all front panel functions

1X

Exe1

]

Enable Lock mode 1.

Lock advanced front panel functions

2X

Exe2

]

Enable Lock mode 2.

Unlock all front panel functions

0X

Exe0

]

Enable Lock mode 0.

View lock status

X

X#]

NOTE:

X!

= Input number (for tie)

00

– (maximum number of inputs for your model) (

00

= untied)

X@

= Output number

01

– (maximum number of outputs for your model)

X#

= Lock mode

0

= mode 0

1

= mode 1

2

= mode 2

X(

= Global or room preset number

00

-

32

,

10

maximum for a room preset (

00

= current configuration for view only)

X1)

= Room number (for room presets)

10

max. (Each can have up to 10 presets (

X(

s) assigned.)

X1!

= Name

12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.

CrossPoint and MAV Series Matrix Switchers • Programming Guide 103