Switcher error responses – Extron Electronics MAV Plus Series User Guide User Manual

Page 99

Advertising
background image

Sprnn

]

The switcher initiates the

Spr

message when a memory preset has been saved from the

front panel. “

nn

” is the preset number.

Rprnn

]

The switcher initiates the

Rpr

message when a memory preset has been recalled from the

front panel. “

nn

” is the preset number.

Innn

Audxx

]

The switcher initiates the

Aud

message when a front panel input audio level change has

occurred. “

n

” is the input number and “

xx

” is the dB level.

Outnn

Volxx

]

The switcher initiates the

Vol

message when a front panel output audio volume change has

occurred.

nn

is the output number and

xx

is the volume level.

Vmtnn*x

]

The switcher initiates the

Vmt

message when an output video mute is toggled on or off from

the front panel.

nn

is the output number and

x

is the mute status: 1 = on, 0 = off.

Amtnn*x

]

The switcher initiates the

Amt

message when an output audio mute is toggled on or off from

the front panel.

nn

is the output number and

x

is the mute status: 1 = on, 0 = off.

Exen

]

The switcher initiates the

Exe

message when the front panel security lockout (executive

mode) is toggled on or off from the front panel. “

n

” is the executive mode: 0, 1, or 2.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the
command and sends a response to the host device. If the switcher is unable to perform
the command because the command is invalid or contains invalid parameters, the switcher
returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (out of range)
E10 — Invalid command
E11 — Invalid preset number (out of range)
E12 — Invalid output number (out of range)
E13 — Invalid value (out of range)
E14 — Invalid command for this configuration
E17 — Timeout (caused only by direct write of global presets)
E22 — Busy
E24 — Privileges violation (Users have access to all view and read commands [other than

the administrator password], and can create ties, presets, and audio mutes

E25 — Device not present
E26 — Maximum number of connections exceeded
E27 — Invalid event number
E28 — Bad filename / file not found

CrossPoint and MAV Series Matrix Switchers • Programming Guide

93

Advertising
This manual is related to the following products: