Configuring the crosspoint or – Extron Electronics MAV Plus Series User Guide User Manual

Page 157

Advertising
background image

Configuring the CrossPoint or MAV Plus Switcher for Network
Use via the ARP Command

The ARP (address resolution protocol) command tells your computer to associate the MAC
(media access control) address of the CrossPoint or MAV Plus switcher with the assigned
IP address. You must then use the ping utility to access the controller, at which point the IP
address of the controller is reconfigured.
Use ARP to configure the IP address as follows:

1.

Obtain a valid IP address for the CrossPoint or MAV Plus switcher from your network
administrator.

2.

Obtain the MAC address (UID #) of the CrossPoint or MAV Plus switcher from the label
on its rear panel. The MAC address should have this format: 00-05-A6-xx-xx-xx.

3.

If the CrossPoint or MAV Plus switcher has never been configured and is still set for
factory defaults, proceed to step 4. If not, perform a mode 4 system reset and then
proceed to step 4. For detailed information on reset modes, see

Performing Soft

System Resets (Resets 3, 4, and 5)

on page 80.

NOTE: The CrossPoint or MAV Plus switcher must be configured with the factory

default IP address (192.168.254.254) before the ARP command is executed, as
described below.

4.

At the PC, access the Command prompt (see

Pinging to Determine the Extron IP

Address

on the preceding page, steps 1 through 3), then enter the

arp –s

command.

Type in the desired new IP address for the unit (obtained in step 1) and the MAC
address of the unit (from the rear panel of the unit), for example

arp –s 10.13.197.7 00-05-A6-03-69-B0

and then press <Enter>.

The computer returns the command prompt (

C:\

).

After you issue the

arp -s

command, the controller changes to the new address and

starts responding to the ping requests to the new address, as described in the next
step.

NOTE: You

must ping the switcher for the IP address change to take place. The

response should show the new IP address, as shown in figure 103.

5.

Execute a ping command by entering ping followed by a space and the new IP address
at the command prompt. For example:

ping 10.13.197.7

C:\>ping 10.13.197.7

Pinging 10.13.197.7 with 32 bytes of data:

Reply from 10.13.197.7: bytes=32 time<10ms TTL=128

Reply from 10.13.197.7: bytes=32 time<10ms TTL=128

Reply from 10.13.197.7: bytes=32 time<10ms TTL=128

Reply from 10.13.197.7: bytes=32 time<10ms TTL=128

Ping statistics for 10.13.197.7:

Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),

Approximate round trip times in milli-seconds:

Minimum = 0ms, Maximum = 0ms, Average = 0ms

Figure 103.

Ping with New Address

TIP: You can reconnect using either Telnet or a web browser to verify that the up-

date was successful.

CrossPoint and MAV Series Matrix Switchers • Ethernet Connection 151