Command and response table for, Ip- and remote port specific, Commands – Extron Electronics MAV Plus Series User Guide User Manual

Page 113: Sis commands, Symbol definitions

Advertising
background image

Command and Response Table for

IP- and Remote Port Specific

SIS Commands

Symbol definitions

X3)

= Matrix name

(Up to 24 alphanumeric characters)

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 109).

X3!

= Default name

Model name

+ last 3 pairs of MAC address.

nn

= 16 or 32.

X3@

= Time and date (for set)

In the format: MM/DD/YY•HH:MM:SS where:
MM = month:

01

(January) through

12

(December)

DD =

01

through

31

YY =

00

through

99

HH =

00

through

23

MM =

00

through

59

SS =

00

through

59

X3#

= Time and date (for read)

In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where:
Day of the week:

Mon

through

Sun

DD =

01

through

31

Mmm = month:

Jan

through

Dec

YYYY =

2000

through

2099

HH =

00

through

23

MM =

00

through

59

SS =

00

through

59

X3$

= GMT offset

–12

.

0

through

+14

.

0

. Hours and minutes removed from GMT

X3%

= Daylight Savings Time

0

= Daylight Savings Time off or ignore

1

= Daylight Savings Time on (North America)

2

= Daylight Savings Time on (Europe)

3

= Daylight Savings Time on (Brazil)

X3^

= IP address

###.###.###.###

X3&

= Hardware (MAC) address

##-##-##-##-##-##

X3*

= Number of open connections

000

-

200

X3(

= Password

Up to 12 alphanumeric characters

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 109).

X4)

= Domain name

Standard domain name rules apply (for example: xxx.com)

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters

on page 109). The @ character is

acceptable only as the lead-in to the domain name (such as @extron.com).

X4!

= E-mail account

65

-

72

.

65

= e-mail recipient 1,

66

= 2,

67

= 3, ...

72

= recipient #8

X4@

= E-mail address

Typical e-mail address format (for example: [email protected])

X4#

= Notify when?

0

= no response

3

= both 1 & 2

1

= fail or missing

4

= suspend

2

= fixed or restored

X4$

= Notification selections

Matrix size 2412 and larger:

01

-

32

= input 1 through input 32

98

= power supplies

99

= fans

Matrix size 1616 and smaller:

01

-

17

= input 1 through input 16

17

= power supply

X4%

= Notify status (for read)

34- or 17-digit number. For each digit:

0

= do not notify,

1

= notify

X4^

= DHCP

0

= off,

1

= on

X4&

= Port number

00

= All ports

01

= Rear panel Remote RS-232/RS-422 port

02

= Front panel Configuration port

X4*

= Baud rate

9600

,

19200

,

38400

,

115200

X4(

= Parity

odd, even, none, mark, space (only the first letter required)

X5)

= Data bits

7

,

8

X5!

= Stop bits

1

,

2

X5@

= Port type

0

= RS-232

1

= RS-422

CrossPoint and MAV Series Matrix Switchers • Programming Guide 107