Table 5.

Reset Mode Comparison and Summary

Mode

Activation

Result

Purpose and Notes

1

Hold down the recessed Reset button while
applying power to the switcher.

NOTE: After a mode 1 reset, update

the switcher firmware to the
latest version. Do not operate the
switcher firmware version that
results from the mode 1 reset. If
you want to use the factory default
firmware, you must upload that
version again (see

Updating the

Firmware

on page 119 for details

on uploading firmware).

The switcher reverts to the factory default firmware.
Event scripting will not start if the switcher is powered on
in this mode. All user files and settings (such as drivers,
adjustments, and IP settings) are maintained.

NOTE: If you do not want to update firmware,

or you performed a mode 1 reset by mistake,
cycle power to the switcher to return to the
firmware version that was running before the
mode 1 reset. Use the

0Q

SIS command to

confirm that the factory default firmware is no
longer running (look for the asterisk [*] following
the version number.

Use mode 1 to revert
to the factory default
firmware version if
incompatibility issues
arise with user-loaded
firmware.

3

Hold down the Reset button for about 3
seconds, until the Reset LED blinks once,
then press and release Reset (<1 second)
within 1 second.

Mode 3 turns events on or off. During resetting, the
Reset LED flashes 2 times if events are starting, 3 times if
events are stopping.

Mode 3 is useful for
troubleshooting.

4

Hold down the Reset button for about
6 seconds, until the Reset LED blinks
twice (once at 3 seconds and again at
6 seconds). Then press and release Reset
(<1 second) within 1 second.

Mode 4:

Enables ARP capability.

Sets the IP address to the factory default.

Sets the subnet address to the factory default.

Sets the gateway address to the factory default.

Sets port mapping to the factory default.

Turns DHCP off.

Turn events off.

The Reset LED flashes four times in quick succession
during the reset.

Mode 4 enables you
to set IP address
information using ARP
and the MAC address.

5

Hold down the Reset button for about
9 seconds, until the Reset LED blinks
three times (once at 3 seconds, again at
6 seconds, and then again at 9 seconds).
Then press and release Reset (<1 second)
within 1 second.

NOTE: Mode 5 reset clears most

adjustments. To save these
settings, use the Matrix Switchers
Control Program and the

File

>

Save

MATRIX

settings

as

...

selection before you perform this
reset (see page 124).

Mode 5 performs a complete reset to factory
defaults (with the exception of the firmware)
:

Does everything mode 4 does.

Resets most real time adjustments, including:

clears all ties and presets,
clears all mutes,
clears all I/O grouping
clears all RGB delay settings to zero
clears all audio settings.

Resets all IP options.

Removes/clears all files for the switcher.

The reset LED flashes four times in quick succession
during the reset.

Mode 5 is useful if
you want to start over
with configuration and
uploading or to replace
events.