Default ip addresses, Establishing a connection, Connection timeouts – Extron Electronics MAV Plus Series User Guide User Manual

Page 97: Number of connections

Advertising
background image

Default IP addresses

To access the CrossPoint or MAV Plus switcher via the LAN port, you need the IP address
for the unit, and may need the subnet mask and the gateway address. If the IP address has
been changed to an address comprised of words and characters, you can determine the
actual numeric IP address using the ping (ICMP) utility (see

Ethernet Link

on page 149 for

more details). If the addresses have not been changed, the factory-specified defaults are:

IP address 192.168.254.254

Subnet mask 255.255.0.0

Gateway address 0.0.0.0

Establishing a Connection

Establish a network connection to CrossPoint or MAV Plus switcher as follows:

1.

Open a TCP socket to port 23 using the IP address of the switcher.

NOTE: If the local system administrators have not changed the value, the factory-

specified default, 192.168.254.254, is the correct value for this field.

The switcher responds with a copyright message including the date, the name of the
product, firmware version, part number, and the current date/time.

NOTES:

If the switcher is

not password-protected, the device is ready to accept SIS

commands immediately after it sends the copyright message.

If the switcher

is password-protected, a

password

prompt appears below the

copyright message.

2.

If the switcher is password protected, enter the appropriate administrator or user
password.
If the password is accepted, the switcher responds with

Login User

or

Login

Administrator

.

If the password is not accepted, the

Password

prompt reappears.

Connection Timeouts

The Ethernet link times out after a designated period of time of no communications. By
default, this timeout value is set to five minutes but the value can be changed. See the

Configure port timeout

SIS commands on page 109.

NOTE: Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (

Q

) command to keep the connection active. If there are long idle

periods, Extron recommends disconnecting the socket and reopening the connection
when another command must be sent.

Number of Connections

A CrossPoint or MAV Plus switcher can have up to 200 simultaneous TCP connections,
including all http sockets and telnet connections. When the connection limit is reached, the
switcher accepts no new connections until some have been closed. No error message or
indication is given that the connection limit has been reached. To maximize performance
of an IP Link device, the number of connections should stay low and unnecessary open
sockets should be closed.

CrossPoint and MAV Series Matrix Switchers • Programming Guide