Special characters, See the, Set serial ports – Extron Electronics MAV Plus Series User Guide User Manual

Page 115: Parameters

Advertising
background image

Command and Response Table for IP- and Remote-Port-Specific SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

IP and Remote port setup commands (continued)

Set e-mail events for recipient

EX4!

,

X4#

,

X4$

,

X4$

,

...

,

X4$

EM

}

You must first have set an e-mail
recipient for the e-mail account number
(

X4!

), using the separate Set e-mail (CR)

command (see the previous page).

Ipe

X4%]

Example:
CrossPoint 450 Plus 3232

E

72,3,1,2,8,32,98,99,EM

}

Ipe•[email protected]

]

E-mail account #72, JSmith, will
receive fail/missing and fixed/restored
messages for input signals 1, 2, 8, and
32; fans; and power supplies.

Read e-mail event notifications for
one account (recipient)

EX4!

EM

}

X4$

,

X4$

,

X4$

, ... ,

X4$]

Response description:

Notify-what?,Inputs 1-32 (inputs above the matrix size are always zero),fans,PS

]

Example:
CrossPoint 450 Plus 3232

EX4!

EM

}

See below

Response:

Notify failed and fixed

3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

01

Input:

02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Fans

Power Supplies

E-mail input 8 status

E-mail power supply and fan status

Ignore input 16

0 0 0 0 0 0 0 0 1 1 1

Example:

MAV Plus 1616

EX4!

EM

}

See below

Response:

Notify failed and fixed

3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1

01

Input:

02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Power Supply

E-mail input 8 status

Ignore input 16

Set DHCP on or off

EX4^

DH

}

Idh

X4^]

Default: 0 (Off)

Read DHCP on/off status

E

DH

}

X4^]

Set serial port parameters

EX4&

*

X4*

,

X4(

,

X5)

,

X5!

CP

}

Cpn

X4&

•Ccp

X4*

,

X4(

,

X5)

,

X5!]

Read serial port parameters

EX4&

CP

}

X4*

,

X4(

,

X5)

,

X5!]

Configure flow control

EX4&

*

X5$

,

X8&

CF

]

Cpn

X4&

•Cfl

X8^

,

X5%]

Read flow control

EX4&

CF

]

X5$

,

X5%]

Configure receive timeout

EX4&

*

X5^

,

X8(

CE

]

Cpn

X4&

•Cce

X8*

,

X5&]

Read receive timeout

EX4&

CE

]

X5^

,

X5&]

Set mode

EX4&

*

X5@

CY

}

Cpn

X4&

•Cty

X5@]

Read mode

EX4&

CY

}

X5@]

Set verbose mode

EX5#

CV

}

Vrb

X5#]

Read verbose mode

E

CV

}

X5#]

Configure current port timeout

E

0*

X5*

TC

}

Pti0*

X5*]

Read current port timeout

E

0TC

}

X5*]

Configure global IP port timeout

E

1*

X5*

TC

}

Pti1*

X5*]

Read global IP port timeout

E

1TC

}

X5*]

Special Characters

The HTML language reserves certain characters for specific functions. The switcher does
not accept these characters as part of names, passwords, or locally created file names.
The switcher following characters are invalid or not recommended:
{space (spaces

are ok for names)} + ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;) colon (:) |

\ and ?.

CrossPoint and MAV Series Matrix Switchers • Programming Guide 109

Advertising
This manual is related to the following products: