Performing Soft System Resets (Resets 3, 4, and 5) —

CrossPoint Ultra and MAV Plus 88, 128, 816, 164, 168, 1212, 1616, 248, and 328 Matrix Sizes

Perform a soft reset of the switcher as follows:

1.

Use a small screwdriver to press and

hold the rear panel Reset button until the Reset

LED and the front panel Video and Audio buttons blink the number of times for the
desired reset: once (events reset), twice (system reset), or three times (absolute reset)
(see figure 55).

I / O

RGBHV

AUDIO

RESET

RESET

RESET

I / O

RGBHV

AUDIO

RESET

RESET

RESET

I / O

RGBHV

AUDIO

RESET

RESET

RESET

Release, then immediately
press and release again.

Release, then immediately
press and release again.

IP Settings

Reset

6 seconds

Absolute Reset

9 seconds

Press and hold
the Reset button.

3 seconds

Events Reset

Front panel I/O buttons flash once.

Reset LED flashes once.

Release, then immediately
press and release again.

Reset LED flashes twice.

Press and hold
the Reset button.

Press and hold
the Reset button.

Reset LED flashes

three times.

Front panel I/O buttons flash twice.

Front panel I/O buttons flash three times.

(Mode 4)

(Mode 5)

(Mode 3)

Figure 55.

Soft System Resets

2.

Release the Reset button and then immediately press and release the Reset button
again. Nothing happens if the second momentary press does not occur within 1 second.