3.

Change a value: Press and release the button that relates to the desired value.

C O N T R O L

PRESET

ENTER

I / O

RGBHV AUDIO

ESC

VIEW

Press and release the button(s) to configure the port as
follows:
Baud rate:
Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

Serial protocol:
RGBHV or Video — RS-232

Audio — RS-422/RS-485

The selected buttons blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

4.

Exit the Serial Port Selection and Configuration mode: Press and release an
output button.

C O N T R O L

PRESET

ENTER

I / O

RGBHV AUDIO

ESC

VIEW

5

All Control and I/O buttons return to unlit or background illumination.

Press and release an

input or output button.

Rear Panel Reset Operations

The rear panel has a Reset button that initiates various levels of resets,

RESET

LAN

dependant on the switcher model and defined in the table below:

Switcher model or

MAV Plus switcher matrix size

Reset

LED

Resets

All CrossPoint Ultra
MAV Plus 88, 128, 816, 164,
168, 1212, 1616, 248, and 328

Yes

Comparable to IPL
modes 3, 4, and 5
Hard reset (IPL mode 1)

All CrossPoint 450 Plus
MAV Plus 2412, 2424, 3216,
and 3232

No

Whole switcher reset
Absolute reset
Hard reset

For different reset levels, press and hold the button while the switcher is running or press
and hold the button while you apply power to the switcher. The Reset button is recessed, so
use an Extron Tweeker, a pointed stylus, or a ballpoint pen to access it.