Performing a system reset from the front panel, Performing a system reset from the, Front panel – Extron Electronics MAV Plus Series User Guide User Manual

Page 82: Resets, Performing front panel resets

Advertising
background image

Selecting Lock mode 2 or toggling between mode 2 and mode 1

NOTE: If the switcher is in Lock mode 0 or mode 1, this procedure selects mode 2.

If the switcher is in Lock mode 2, this procedure selects mode 1.

Toggle the lock on and off by pressing and holding the RGBHV (CrossPoint Ultra) or Video
(MAV Plus) button and the Audio button for approximately 2 seconds (see figure 52).

I / O

VIDEO AUDIO

I / O

VIDEO AUDIO

Press and hold the buttons simultaneously to turn on
Lock mode 2 or to toggle between mode 1 and mode 2.

2 seconds

The buttons blink
twice to indicate the
mode change.
Release the buttons.

Figure 52.

Toggle Front Panel Lock Between Mode 2 and Mode 1

Performing a System Reset from the Front Panel

The front panel reset is identical to issuing the

EZXXX}

SIS command defined on

page 104. A system reset performs the following functions:

Clears all ties and presets

Clears all video and audio mutes

Resets all I/O grouping

Resets all RGB delay to 0 seconds

Resets all input audio levels to unity gain (0 dB)

Sets all output volume levels to 100% (0 dB of attenuation)

NOTES:

System reset does

not reset the Internet protocol (IP) settings or replace user-

installed firmware.

The system reset clears most image and audio adjustments. To save these settings,
use the Windows-based Matrix Switchers Control Program and the

File

>

Save

MATRIX

settings

as

... selection (see page 124) before you perform this reset.

If background illumination was turned on before the reset, the I/O and control
buttons are unlit after the reset. But, when you cycle power, background illumination
returns to as selected.

Reset the switcher to the factory default settings by pressing and

holding the RGBHV

(CrossPoint switchers) or Video (MAV Plus switchers) button and Audio button
simultaneously

while you apply AC power to the switcher (see figure 53).

I / O

VIDEO

AUDIO

Press and hold the buttons while you
apply power to the switcher.

Release the buttons.

Power

The switcher flashes
the button indicators
and then turns them off.

Continue to hold the buttons until all input
and output buttons return to either unlit or
to background illumination and the RGBHV
or Video and Audio buttons turn on.

Figure 53.