Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 115

Advertising
background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

101

STX KtD

Write Data Storage Format Identifier (DSFID) to Tag

(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)

This command writes the DSFID data to the tag.

Syntax:

<STX>KtDabcc

Where:

a

- The number of retry attempts, 0-9.

b

- Lock the Data Storage Format Identifier (DSFID) after writing:

0 = No Protection
1 = Write Protect

cc

- Two character DFSID value representing one byte.

Sample:

<STX>KtD91C3[CR]

The sample writes 0xC3 DSFID byte, locking value, retrying nine times, if necessary.






STX KtE

Write Electronic Article Surveillance (EAS) Bit

(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)

This command writes the EAS bit for Philips ISO tags.

Syntax:

<STX>KtEabcc

Where:

a

- The number of retry attempts, 0-9.

b

- Electronic Article Surveillance (EAS) option:

0 = Set EAS
1 = Reset EAS
2 = Test EAS

cc

- Two character Manufacturer’s Code, representing one byte.

Sample:

<STX>KtE9004[CR]

The sample writes the EAS bit for Philips (0x04), retrying nine times, if necessary.



Advertising