Extended System-Level Command Functions






Class Series Programmer’s Manual

81


Value

Units / Interpretation

RFID Configuration Definition / Function

Tn

where n:

0 = ISO 15693
1 = Texas Instruments
2 = Philips
3 = ST Micro LRI 512
4 = ST Micro LRI 64

Establishes the tag type (HF only).

Nn where

n:

64 = 64-bit
96 = 96-bit

Sets the UHF tag data size (Samsys UHF only).

Un where

n:

0 = EPC 0
1 = EPC 0+ Matrics
2 = EPC 0+ Impinj
3 = EPC 1
4 = ISO 18000-6A
5 = ISO 18000-6B
6 = UCODE EPC 1.19
7 = EM 4022/4222
8 = Gen 2

Sets the UHF tag type (Samsys UHF only).

Vn where

n:

= a value from -4 to +4 Adjusts the power, in dBmn (Samsys UHF only).

Table 5-8: RFID Configuration Set Commands (continued)


Example:

<STX>KcRIMH;RIA11E;RID22E;RIS04;RIR3;RIWE;RIEE;RIP000<CR>

The above example sets the printer to HF, protect after write AFI 11, protect after write DFSID 22, set EAS Bit (Mfg. Code 0x04), allow 3 tries
for each read or write attempt, lock after writing, erase the tag if there is an error, and use a position of 0.00.