Value
Units / Interpretation
RFID Configuration Definition / Function
Tn
where n:
0 = ISO 15693
1 = Texas Instruments
2 = Philips
3 = ST Micro LRI 512
4 = ST Micro LRI 64
Establishes the tag type (HF only).
Nn where
n:
64 = 64-bit
96 = 96-bit
Sets the UHF tag data size (Samsys UHF only).
Un where
n:
0 = EPC 0
1 = EPC 0+ Matrics
2 = EPC 0+ Impinj
3 = EPC 1
4 = ISO 18000-6A
5 = ISO 18000-6B
6 = UCODE EPC 1.19
7 = EM 4022/4222
8 = Gen 2
Sets the UHF tag type (Samsys UHF only).
Vn where
n:
= a value from -4 to +4 Adjusts the power, in dBmn (Samsys UHF only).
Table 5-8: RFID Configuration Set Commands (continued)
Example:
<STX>KcRIMH;RIA11E;RID22E;RIS04;RIR3;RIWE;RIEE;RIP000<CR>
The above example sets the printer to HF, protect after write AFI 11, protect after write DFSID 22, set EAS Bit (Mfg. Code 0x04), allow 3 tries
for each read or write attempt, lock after writing, erase the tag if there is an error, and use a position of 0.00.