Stx kx delete configuration file, Stx kz immediately set parameter – Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 122
Extended System-Level Command Functions
Class Series Programmer’s Manual
108
STX Kx
Delete Configuration File
(Display-Equipped Models only)
This command deletes the specified configuration file.
Syntax:
<STX>KxmName<CR>
Where:
m
-
Valid Module ID – Range A to Z.
Name
-
The name, up to 16 characters, of the configuration file.
<CR>
-
0x0d terminates the name.
Sample:
<STX>KxYPlant1
This command deletes the configuration file Plant1 located on Module Y. (Remember to prefix this
command with the Module (Un)Protect Command <STX>Kp.)
STX KZ
Immediately Set Parameter
This command immediately sets the specified parameter.
Syntax:
<STX>KZax<CR>
Where:
a
-
Valid parameter identifier, as follows:
F =
Feed Speed
H =
Heat Setting
P =
Print Speed
S =
Slew Speed
x
- Speed Parameter Range – A to e (see Appendix L).
-or-
xx
-
Heat Parameter Range – A two-digit value (00-30); see the
‘H’ Label Formatting Command.
Sample:
<STX>KZH22
This command causes the file currently being executed to assume a Heat Value of 22.