Stx kx delete configuration file, Stx kz immediately set parameter – Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 122

Advertising
background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

108

STX Kx

Delete Configuration File

(Display-Equipped Models only)

This command deletes the specified configuration file.

Syntax:

<STX>KxmName<CR>

Where:

m

-

Valid Module ID – Range A to Z.

Name

-

The name, up to 16 characters, of the configuration file.

<CR>

-

0x0d terminates the name.

Sample:

<STX>KxYPlant1

This command deletes the configuration file Plant1 located on Module Y. (Remember to prefix this
command with the Module (Un)Protect Command <STX>Kp.)






STX KZ

Immediately Set Parameter

This command immediately sets the specified parameter.

Syntax:

<STX>KZax<CR>

Where:

a

-

Valid parameter identifier, as follows:

F =

Feed Speed

H =

Heat Setting

P =

Print Speed

S =

Slew Speed

x

- Speed Parameter Range – A to e (see Appendix L).

-or-

xx

-

Heat Parameter Range – A two-digit value (00-30); see the
‘H’ Label Formatting Command.

Sample:

<STX>KZH22

This command causes the file currently being executed to assume a Heat Value of 22.

Advertising