Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 248

Advertising
background image

Appendix J – General Purpose Input Output Ports

Class Series Programmer’s Manual

234

GPI/O A (J1)

Four dedicated inputs are available for control of printer functions. These inputs require no external
pull-ups, are designed to interface to open-collector outputs and accept totem pole outputs from +4.5 to +
26 VDC. Optical isolators are available to provide isolation. Two print control circuit examples are given
below.


For direct inputs –

Use the printer’s +5VDC and Ground to supply the devices
interfacing to the GPI/O A inputs (as shown, right).

GPI/O A - J1

3

4

5

6

1

Start of Print

Slew Label

Toggle/Pause

Reprint

Ground






For isolated inputs –

To provide galvanic isolation for the GPI/O A inputs, remove
jumper JMP 9 then supply an external +5VDC source voltage
to Pin 2, and remove jumper JMP 8 then supply an external
Ground to Pin 1 (as shown, right).


3

4

5

6

2

Start of Print

Slew Label

Toggle/Pause

Reprint

Vcc

+5 VDC External Source

GPI/O A - J1

1 Ground



Seven dedicated outputs are available for control, warning, and error functions. These open-collector
outputs are slew-limited. Optional 10K ohm pull-up resistors, tied to a common point for use at either +5
or +24 VDC, are available via jumper JMP 1.

Note: To avoid damage if external pull-up resistors are used (that is, without jumper JMP1 installed), ensure that

the external voltage does not exceed +30VDC.

The table below details the GPI/O A pin assignments, settings and functions:

Advertising