Extended System-Level Command Functions






Class Series Programmer’s Manual

46


<STX>Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Applicable

Printer Type

Menu Item Equivalent

or Menu Item Number

Command

Equivalent

Display-Equipped Print

Control

Darkness

DK

1 – 64

N/A

EX2 N/A

N/A

D, G

Display-Equipped

System Settings

Default Module

DM

A, B

Module Letter

EX2

[3]

N/A

<STX>X

Delay Rate
(Test Label Formats)

DR

0 – 120

Seconds

Display-Equipped

Diagnostics

N/A

Disable Symbol Set
Selection

NS Y,

N

Y = Enabled,
N = Disabled

Non-Display N/A N/A

Display-Equipped System

Settings

Double Byte Symbol Set

DS

2-Byte alpha

character

AA – ZZ, printer

resident symbol set

EX2 N/A

<STX>y,

ySxx

DPI Emulation

DE

200, 300,

400, 600

Dots per inch

300/400/600 DPI

Display-Equipped

System Settings

N/A

Display-Equipped Media

Settings

Empty Sensor Level

EV

0 – 255

N/A

EX2 N/A

N/A

Display-Equipped

End Character

EN

D

N/A

EX2

N/A N/A

Table 5-1: Configuration Set Commands (continued)