Stx o cycle cutter, Stx p set hex dump mode, Stx p controlled pause – Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 38: Stx q clear all modules

Advertising
background image

System-Level Command Functions







Class Series Programmer’s Manual

24

STX o

Cycle Cutter

This command will cause the optional cutter mechanism to immediately perform a cut after all
previously received commands are executed. The cutter must be installed, enabled and the
interlock(s) closed for operation.

Syntax:

<STX>o






STX P

Set Hex Dump Mode

This command instructs the printer to assume Hex Dump Mode. Instead of a formatted product, data
sent to the printer following this command will be printed in the raw ASCII format. To capture this
data, labels must be at least four inches (102 mm) long and as wide as the maximum print width. This
command has the same effect as turning the printer ‘On’ while pressing the FEED Key; however, no
Configuration/Test Pattern label will be printed. To return to normal operation the printer must be
manually reset.

Syntax:

<STX>P






STX p

Controlled Pause

The controlled pause command will cause the printer to pause only after all previously received
commands are executed. This is often useful between label batches. (This command will not clear the
pause condition, see <SOH>B).

Syntax:

<STX>p







STX Q

Clear All Modules

This command instructs the printer to clear all of the Flash and DRAM modules (see the Operator’s
Manual
of the corresponding printer for applicable module options). All stored data will be
destroyed.


Syntax:

<STX>Q

Advertising