<STX>Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Applicable

Printer Type

Menu Item Equivalent

or Menu Item Number

Command

Equivalent

Display-Equipped Media

Settings

Reflective Paper Value

RV

0 – 255

N/A

EX2 N/A

N/A

Reflective TOF Bias

[2]

RB

0 – 50

.1 Volt DC

Non-Display

(except EX2)

14 N/A

Reflective TOF Delta

[2]

RD

0 – 50

.1 Volt DC

Non-Display

(except EX2)

13 N/A

Reflective TOF Gain

[2]

RG

0 – 15

.1 Volt DC

Non-Display

(except EX2)

12 N/A

Retract Delay

RW

1 – 255

Specified value,

multiplied by ten

milliseconds

Display-Equipped Printer

Options

N/A

Rewinder Equipped

RM

A/Y, E, N/D

A or Y = Auto,

E = Enabled,

N or D = Disabled

Display-Equipped Printer

Options

N/A

Rewinder Adjust

RR

-xx, +yy

Applied torque, where

-30 to +15 is the valid

range.

Display-Equipped Printer

Options

N/A

RFID Configuration

RI

M, A, D, S,

L, R, W, E, P,

T, N, U, V

See Table 5-8.

Display-Equipped

Printer Options

N/A