Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 69
Extended System-Level Command Functions
Class Series Programmer’s Manual
55
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Media
Settings
Reflective Paper Value
RV
0 – 255
N/A
EX2 N/A
N/A
Reflective TOF Bias
[2]
RB
0 – 50
.1 Volt DC
Non-Display
(except EX2)
14 N/A
Reflective TOF Delta
[2]
RD
0 – 50
.1 Volt DC
Non-Display
(except EX2)
13 N/A
Reflective TOF Gain
[2]
RG
0 – 15
.1 Volt DC
Non-Display
(except EX2)
12 N/A
Retract Delay
RW
1 – 255
Specified value,
multiplied by ten
milliseconds
Display-Equipped Printer
Options
N/A
Rewinder Equipped
RM
A/Y, E, N/D
A or Y = Auto,
E = Enabled,
N or D = Disabled
Display-Equipped Printer
Options
N/A
Rewinder Adjust
RR
-xx, +yy
Applied torque, where
-30 to +15 is the valid
range.
Display-Equipped Printer
Options
N/A
RFID Configuration
RI
M, A, D, S,
L, R, W, E, P,
T, N, U, V
See Table 5-8.
Display-Equipped
Printer Options
N/A
Table 5-1: Configuration Set Commands (continued)