Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 59
Extended System-Level Command Functions
Class Series Programmer’s Manual
45
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Communications
Y, N
EX2 N/A
Comm TOF Commands
CT
0 – 255
(128 nominal)
Y = Enabled,
N = Disabled
Non-Display
(except EX2)
27
N/A
Display-Equipped Media
Settings
Non-Display 12
Continuous Label Length
CL
0 – 9999
1/100 in.
Non-Display 10
<STX>c
Display-Equipped Communications
Non-Display 11
N/A
Control Codes
CC
S, 1, 2
S = Standard,
1 = Alternate,
2 = Alternate-2
Non-Display 9
<STX>KD
Cut Behind
CB
0 – 9
Queued label count
Display-Equipped
Printer Options
N/A
A/Y, E, N/D
A or Y = Auto,
E = Enabled,
N or D = Disabled
Display-Equipped Printer
Options
Cutter Equipped
CE
A, E/Y, N
A = Auto,
E or Y = Enabled,
N = Disabled
Non-Display 4
<STX>V
Table 5-1: Configuration Set Commands (continued)