Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 57

Advertising
background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

43

Configuration Set Commands

<STX>Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Applicable

Printer Type

Menu Item Equivalent

or Menu Item Number

Command

Equivalent

Non-Display 19

Alignment Length

AL

0 – 999

1/100 inch

Non-Display 18

N/A

Display-Equipped

System Settings

Backup After Print

BA

Y, N

Y = Enabled,
N = Disabled

EX2 N/A

N/A

Backup Delay

BD

0 – 255

1/50 second

Display-Equipped

System Settings

N/A

Backup Label

BL

0, 3, 4

0 = Disabled,

3 = Active Low,

4 = Active High

Display-Equipped

Printer Options

N/A

Display-Equipped

Print Control

Backup (Reverse) Speed

BS

or bS

alpha

character

Model specific ranges;

see Appendix L.

EX2 N/A

pa

Display-Equipped

British Pound

BP

Y, N

Y = Enabled,

N = Disabled

EX2

N/A

N/A

Buzzer Enable

BZ

Y, N

Y = Enabled,
N = Disabled

A-Class

System Settings

N/A

Table 5-1: Configuration Set Commands