Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 57
Extended System-Level Command Functions
Class Series Programmer’s Manual
43
Configuration Set Commands
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Non-Display 19
Alignment Length
AL
0 – 999
1/100 inch
Non-Display 18
N/A
Display-Equipped
System Settings
Backup After Print
BA
Y, N
Y = Enabled,
N = Disabled
EX2 N/A
N/A
Backup Delay
BD
0 – 255
1/50 second
Display-Equipped
System Settings
N/A
Backup Label
BL
0, 3, 4
0 = Disabled,
3 = Active Low,
4 = Active High
Display-Equipped
Printer Options
N/A
Display-Equipped
Print Control
Backup (Reverse) Speed
BS
or bS
alpha
character
Model specific ranges;
see Appendix L.
EX2 N/A
pa
Display-Equipped
British Pound
BP
Y, N
Y = Enabled,
N = Disabled
EX2
N/A
N/A
Buzzer Enable
BZ
Y, N
Y = Enabled,
N = Disabled
A-Class
System Settings
N/A
Table 5-1: Configuration Set Commands