Extended System-Level Command Functions






Class Series Programmer’s Manual

47

<STX>Kc

Parameter Name

Parameter

Pneumonic

Value /

Range

Units /

Interpretation

Applicable

Printer Type

Menu Item Equivalent

or Menu Item Number

Command

Equivalent

End Of Print

EP

1, 2, 3, 4

1 = Low Pulse,

2 = High Pulse,

3 = Active Low,

4 = Active High

Display-Equipped

Printer Options

N/A

Display-Equipped Communications

ESC Sequences

ES

Y, N

Y = Enabled,
N = Disabled

EX2 N/A

N/A

Exact Time

ET

Y, N

Y = Enabled,
N = Disabled

Non-Display

(except EX2)

24 N/A

Display-Equipped System

Settings

EX2 N/A

Fault Handling

FH

L, D, R, B

See Table 5-2.

Non-Display 24

N/A

Feed Speed

SS

or sS

Alpha

character

Model specific ranges;

see Appendix L.

Display-Equipped

Print Control

Sa

Display-Equipped Communications

Feedback Mode

FM

Y, N

Y = Enabled,
N = Disabled

EX2 N/A

<STX>a

Display

Font Emulation

FE

0, 1, 2

0 = No Substitution

1 = Sub CG Times SA0

2 = Sub User S50

Non-Display

N/A N/A

Table 5-1: Configuration Set Commands (continued)