Extended System-Level Command Functions






Class Series Programmer’s Manual

72

(MCC) Module Command – This command adjusts the size of Flash module on the optional
Expansion Card according to the table below (see Appendix K for appropriate module details):


Value

Module Command Units / Interpretation

Zxx xx

=

Size: 1 – 7 Mbytes. This is the amount to be allocated to Module

Z

; any remaining

memory will be allocated to Module

F

.

Gxx xx

=

Size: 1 – 56, in 128 Kbytes blocks. This is the amount to be allocated to Module

G

;

any remaining memory will be allocated to Module

X

.

Table 5-4: Module Command







(ML) Maximum (Label) Length
See <STX>M for command details.






(MM) Menu Mode –
This command sets the menu access level of the printer – where User is a
basic listing of menu settings and controls, and Advanced is a full menu listing.






(MT) Media Type –
This command selects the printing method: Direct Thermal for use with heat
sensitive media or Thermal Transfer for use with media requiring a ribbon to create an image.
(For non-display models also see the <STX>KD command.)






(MV) Mark Value
This command sets threshold value for the reflective media sensor’s ‘mark’
parameter.