B bar code magnification, Cset column offset amount – Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 125

Advertising
background image

Label Formatting Command Functions






Class Series Programmer’s Manual

111

B Bar

Code

Magnification

(Display-Equipped Models only)

This command provides a mechanism to specify bar codes greater than 36 dots (0-9,A-Z in the field
record). The value is reset to 1 at the start of every label and stays active for the entire label or set to
a new value.

Syntax:

Bnn

Where:

nn

- Is a two digit decimal number indicating the magnification

value.

Sample:

<STX>L<CR>
D11
B01
1a9305000100030ABCD<CR>
B03
1a3105000700030ABCD<CR>
Q0001
E

The sample instructs the printer to print two bar codes, each 9 dots by 3 dots.





C

Set Column Offset Amount

This command allows horizontal adjustment of the point where printing begins. The printer is
instructed to print label formats nnnn units to the right of the position that the format specifies. This
feature is useful when a single format is to be printed on labels containing preprinted information.

Note: If using preprinted labels where the placement of the preprint data varies from label to label, the

printed information may overlap the preprinted data.


Syntax:

Cnnnn

Where:

nnnn

- Is a four-digit number for the column offset, inches/100 or

mm/10. The printer default is 0 for offset.

Sample:

<STX>L

C0050
141100001000100DATAMAX<CR>

The sample shifts all format data 0.5 inches to the right, unless the printer is in metric mode, (see
Label Formatting Command ‘m’).