Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 88

Advertising
background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

74

Example:

<STX>KcNTI010.012.000.243;NTS255.255.000.000;NTG010.012.254.254;NTDN;
<CR>

The command string above is typical of a network setup string (where the values meanings are
shown in the following table). This configuration setup command string may be included with
any other Kc sub-commands.

Sub-commands and Values

Interpretation

NTI010.012.000.243

IP Address: 10.12.0.243

NTS255.255.000.000

Subnet Mask: 255.255.0.0

NTG010.012.254.254

Gateway Address: 10.12.254.254

NTDN

DHCP is disabled





(NR) No Reprint
This command controls the label reprint function following the correction of a
fault condition. Upon detection of a fault (ribbon out, paper out, etc.), printing stops and a fault
indicator is illuminated. After the problem is corrected, the FEED Key must be pressed to clear
the fault and resume normal operation. When enabled, the label in process is not reprinted.







(NS) Disable Symbol Set Selection
This command prevents the <STX>y and y commands
from changing the default single-byte symbol set. When enabled, DPL Symbol Set commands are
ignored.


Note: When enabled, the only way to change the current symbol set is with the <STX>KcAS

command.