Extended System-Level Command Functions






Class Series Programmer’s Manual

68

(FM) Feedback Mode – See

<STX>a

for command details.




(FS) Slew Speed – This command controls the rate of label movement between printing areas
when the GPIO port is used; see Appendix L for ranges.




(GE) GPIO Equipped – This command is used to interface the printer to external controlling
devices (see Appendix J):


Value

Units / Interpretation

GPIO Enable Definition

A

Applicator

Enables the GPIO for a label applicator.

V

Verifier

Enables the GPIO for a bar code verifier.

N

Disabled

Disables the GPIO Port.




(GM) Gap / Mark Value – This command sets threshold value for the media sensor’s ‘gap /
mark’ parameter.




(GR) Gain Reflective Value – This command sets the sensitivity of the reflective media sensor.




(GS) GPIO Slew – This command sets the GPIO slew function and control:

Value

Slew Interpretation

0

Standard (Active Low)

1

Low Pulse *

2

High Pulse *

3

Slews while low (Active Low)

4

Slews while high (Active High)

* Pulse must be at least 60 milliseconds in length. Functions as if pressing the Feed Key, clearing

alarms and advancing media.