Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 94

Advertising
background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

80

(RI) RFID Configuration

This command configures the optional RFID interface module, as follows:

Table 5-8: RFID Configuration Set Commands

Value

Units / Interpretation

RFID Configuration Definition / Function

D = Disable

Disables the RFID module. (“N” is also a valid disabler.)

H = HF

Enables the RFID module for HF (Securakey).

U = UHF

Enables the RFID module for UHF Class 1 (Alien).

Mn

where n:

M = UHF

Enables the RFID module for UHF Multi-Protocol (Samsys).

AIhh

where hh:

2-Chararacter Hex ID Sets the Application Family Identifier (AFI), (HF only)

ALn

and where n:

E = Enable,

D = Disable

Allows locking the AFI after writing (HF only)

DIhh

where hh:

2-Chararacter Hex ID Sets the Data Storage Format Identifier (DSFID), (HF only)

DLn

and where n:

E = Enable,

D = Disable

Allows locking the DSFID after writing (HF only)

Shh

where hh:

2-Chararacter Hex ID Sets the Electronic Article Surveillance (EAS) set, representing the manufacturer’s code. (HF only)

Lhh

where hh:

2-Chararacter Hex ID Sets the Lock Code (Alien UHF only)

Rn

where n:

0 – 9

Sets the number of retries for RFID functions

Wn

where n:

E = Enable,

D = Disable

Allows locking the tag after writing.

En

where n:

E = Enable,

D = Disable

Allows erasures of the tag on error (HF only)

Pxxx

where xxx: 3-digit

value

Sets the tag encoding position: A value of 0.00 causes the print position to be used; or, a value
greater than 0 causes the presented position to be used. (Subject to change.)

Advertising