Extended System-Level Command Functions






Class Series Programmer’s Manual

77

(PJ) Present Adjust Fine Tune This command fine-tunes the Present Distance setting in dots to
compensate for slight mechanical differences sometimes evident if multiple printers share label
formats.




(PL) Printer Level –
This command is used to upgrade the software feature level of the printer.




(PM) Pause Mode –
See <STX>J for command details.




(PO) Paper Empty –
This command sets the length of travel before an out of stock condition is
declared.




(PP) Parallel Direction –
This command controls the parallel port communications settings:

Value

Parallel Direction Units / Interpretation

xz

x = Port ID: A or B

z = Direction: U (unidirectional – one-way communication); or,

B (bi-directional – IEEE 1284 back-channel operation).

Table 5-7: Parallel Communications Configuration Command





(PS) Present Sensor Equipped
This command allows the printer to sense the present sensor
option. A or Y - automatically senses device presence; if undetected, no error will be generated. E
- enables the device, where its presence must be detected; otherwise, a fault is generated. N or D -
disables device detection. See <STX>V for command details. (Note that the value range for non-
display printers is only Y, or N. Also see the <STX>KD command.)




(pS) Print Speed –
See P (in Label Formatting Command Functions) for command details.