Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 249

Advertising
background image

Appendix J – General Purpose Input Output Ports

Class Series Programmer’s Manual

235

WARNING

Failure to properly configure the GPIO Port can result in damage to the printer and / or connected devices.

Applicator Interface Card (Version 2) GPI/O Port A Overview

Pin

Number

Signal Name

Signal

Direction

[1]

Jumper

Position

Function / Description

Installed

Printer chassis is used.

1

Ground

JMP

8

Removed

Ground must be supplied.

Installed

Printer +5VDC is used (.5 amp maximum)

Note: Drawing more than .5 amps can cause unreliable printer operation.

2

+5 VDC

N/A

JMP 9

Removed

+5VDC must be supplied.

3

Start Of Print

[2]

Programmable

4

Slew Label

Programmable

5

Toggle / Pause

The printer pauses when the signal is taken LOW.

6

Reprint

Input

The last label is reprinted exactly, with no increment or time stamp changes;
recommended for use during error conditions. Always keeping this signal LOW results
in non-stop printing.

7 +24

VDC

Printer +24 VDC (1.5 amp maximum)

8

Ground

N/A

N/A N/A

Printer chassis.

9

Ribbon Low

Programmable

[1]

. Signifies a RIBBON LOW DIAMETER warning condition.

10

Service Required

Evoked by occurrences listed under ‘Fault Messages.’

[1]

Active LOW.

11

End Of Print

Programmable

[1]

. Signifies the End of Print (EOP) process.

12

Media Out

Evoked during an Out of Stock condition. Active LOW.

13

Ribbon Out

Evoked during an Out of Ribbon condition. Active LOW.

14

Data Ready

Evoked when a label is waiting to be printed. Then after the printer receives the Start of
Print signal, printing will begin. For synchronization with the print cycle, the End Of
Print signal indicates the completion of the print process. Active LOW.

15

Option Fault

Output

JMP 1

When inactive, outputs will be pulled up to
a voltage determined by this jumper setting,
where:

Pins 1 – 2 = +5VDC;

Pins 2 – 3 = +24VDC; or,

None = A common external voltage (not
to exceed +30VDC) via external pull-ups
(providing a 20K ohm feedback path
through any two outputs).

Evoked during a Linear Scanner or RFID fault condition. Active LOW.

[1]

Signal directions are given relative to the printer.

[2]

If active with no current print job, “WAITING FOR DATA” will be displayed. Specifying a quantity of 9999 while keeping this signal ON will cause non-stop label printing, except in single label
“Imaging Mode”, which will cause the printer to stop between labels.

Advertising