Extended System-Level Command Functions






Class Series Programmer’s Manual

84

(SL) Stop Location – This command sets the label stopping (and in certain cases the starting)
location, as follows:


Value

Stop Location

A

Automatically sets the stop location. Installed options will be ‘auto-sensed’ and the
appropriate stop position will automatically be set. Host commands are ignored.

H

Sets stop position according to options installed. If no options are installed the printer
sets stop location to the next label’s start of print. Host commands will override. The
stop location (present distance) may be controlled dynamically by the host using the
<STX>f

or <STX>Kf commands. This selection has the same effect as <STX>KD

Ignore Host Distance bit value 0.

P

Sets the stop location to approximately 2 mm behind the peel bar edge, a nominal peel
position. The Present Sensor status and this setting are independent.

C

Sets the stop location to a nominal cut position. For die-cut media, the position is just
following the end of the label. The cutter status and this setting are independent.

T

Sets the stop location to that of the tear bar on the printer cover.

N

Sets the stop location to the start of the next label, equivalent to setting the <STX>KD
Ignore Host Distance bit value 1.

Table 5-10: Stop Location Command










(SM) Maximum (Label) Length Ignore –
This command controls recognition of the <STX>M
command.

Advertising