Extended System-Level Command Functions






Class Series Programmer’s Manual

83

(SA) SOP Adjust – This command sets the start of print (SOP) location, relative to the top of
form. See <STX>O for command details. The

EX2

accepts this command for backward

compatibility only, limited in range (28-228). The <STX>KcQQQ response shows the Row
Adjust Fine Tune (RF) equivalent value.



(SC) Scalable Cache
This command sets the number of 1K blocks allocated for the scaleable
font engine. Available memory dependent upon model; see Appendix K. (For non-display models
see the <STX>KS command.)



(SE) SOP Emulation –
This command enables the <STX>O and <STX>f print positioning
commands to allow backward compatibility with label formats designed for other printers.



(SF) Save As Filename – This command, which may be sent separately or included as the last
command in an <STX>Kc command string, saves the effective printer configuration to a file in
Flash memory with a .dcm file extension.



(SG) Sensor Gain Value –
This command sets the control of the voltage to the LED emitter of
the Media Sensor.



(SH) Scalable Heap –
This command sets a working “scratch pad space” in DRAM for scalable
font construction.



(Sl) Security Lock –
This command provides the ability to password-protect all printer settings
made through the User Interface, as follows:


Value

Security Function

Nxxxx

Where xxxx is the current password, this disables Menu protection.

Yxxxx

Where xxxx is a new password, this enables Menu protection and sets a new password.

Txxxx

Where xxxx is a new password, this enables Menu protection, disables the User
Interface Test Button functions, and sets a new password.

Table 5-9: Security Lock Command

Advertising