Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 250

Advertising
background image

Appendix J – General Purpose Input Output Ports

Class Series Programmer’s Manual

236

GPI/O B (J2)

Six unassigned inputs are designed to interface to open-collector outputs. These inputs require no
external pull-ups and blocking diodes allow the use of totem pole outputs from +4.5 to + 26 VDC. Optical
isolators are available to provide isolation. Two print control interface circuit examples are given below.



For direct inputs:

Use the printer’s +5VDC and Ground to supply the devices
interfacing to the GPI/O B inputs (as shown, right).

GPI/O B - J2

8

3

12

7

Input 1

Ground

13

Input 2

Input 3

Input 4

6

Input 5

Input 6

2









For electrically-isolated inputs:

To provide galvanic isolation for the GPI/O B inputs, remove
jumper JMP 11 then supply an external +5VDC source
voltage to Pin 1, and remove jumper JMP 10 then supply an
external Ground to Pin 6 (as shown, right).



1 Vcc

+5 VDC External Source

GPI/O B - J2

8

3

12

7

Input 1

13

Input 2

Input 3

Input 4

Input 5

Input 6

2

Ground

6


Six unassigned outputs are programmable and slew-limited. Optional 10K ohm pull-up resistors, one for
each of the output lines, can be used at either +5 or +24 VDC via jumpers JMP 2 – 7.

Note: To avoid damage if external pull-up resistors are used (that is, when Jumpers JMP 2 - 7 are not installed),

ensure that the external voltage does not exceed +30VDC.

The table below details the GPI/O B pin assignments, settings and functions: