Class Series Programmer’s Manual
49
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Media
Settings
Head Cleaning
HC
0 – 9999
Inches (or centimeters)
multiplied by 1000
EX2 N/A
N/A
Display-Equipped Print
Control
Non-Display 23
Heat
HE
0 – 30
N/A
Non-Display 21
Hnn
Display-Equipped Communications
Host Timeout
HT
1 – 60
Seconds
EX2 N/A
N/A
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Ignore Control Codes
IC
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A
N/A
Ignore Distances
IE
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A N/A
Display-Equipped System
Settings
EX2 N/A
Imaging Mode
IL
M, S
M = Multiple label,
S = Single label
Non-Display 22
N/A
Table 5-1: Configuration Set Commands (continued)