Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 72
Extended System-Level Command Functions
Class Series Programmer’s Manual
58
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Security Lock
Sl
N, Y, T
See Table 5-9.
Display-Equipped
System Settings
N/A
Display-Equipped
Sensor Gain Value
SG
0 – 32
N/A
EX2
Media Settings
N/A
Display-Equipped Media
Settings
Non-Display
<STX>e,
<STX>r,
<STX>c
Sensor Type
ST
G, C, R
G = Gap (edge),
C = Continuous,
R = Reflective
Non-Display
2
<STX>KD
Display-Equipped Communications
Non-Display
9 & 10
N/A
Serial Port
SP
xyz
See Table 5-12.
Non-Display
7 & 8
<STX>KD
Display-Equipped System
Settings
Single Byte Symbol Set
AS
2-Byte alpha
character
AA – ZZ, printer
resident symbol set
Non-Display N/A
<STX>y,
ySxx
Slew Speed
FS
Alpha
character
Model specific ranges;
see Appendix L.
GPIO-Equipped
Print Control
<STX>KZSx
Table 5-1: Configuration Set Commands (continued)