Description of System

11.8. Safety end positions after failure of the electrical

or pneumatic auxiliary power

The safety end position depends on the fluidic connection of the actuator to the working connections A1 or A2.

Actuator.system

Designation

Safety.end.positions.after.failure.of.the

electrical.auxiliary.power

pneumatic..

auxiliary.power

up

down

single-acting

Control function

A

down

Connection according to “Figure 10”

down

up

Connection according to “Figure 11”

up

down

single-acting

control function

B

up

Connection according to “Figure 10”

up

down

Connection according to “Figure 11”

up

down

lower

chamber

upper

chamber

double-acting

Control function

I

Fluid connection see “Figure 12”

not defined

up = lower chamber of the actuator to A2

down = upper chamber of the actuator to A2

Table 8:

Safety end position

Fluid.connection:.Description for “Table 8”

Single-acting.actuators.
Control function A and B

Double-acting.actuators.

Control function I

Connection:
working connection A1 to actuator

A2 sealing

Connection:
working connection A2 to actuator

A1 sealing

Connection:
Working connection A1 and A2
to actuator

Safety end position:
up = lower chamber to A2
down = upper chamber to A2

Figure 10:

Connection A1

Figure 11:

Connection A2

Figure 12:

Connection with CFI