Follower / follower frequency p1/2 – CONTREX CX-1200 User Manual

Page 114

Advertising
background image

5 - 21

FOLLOWER / FOLLOWER FREQUENCY P1/2

Cnt Mode FI2

Count Mode FI2 (CP-265) identifies the type of encoder that is connected to Frequency Input 2. The “Quad x4” setting
is a for quadrature encoder that gives 4 counts per pulse and also gives direction information. The Incremental
selection is for a single channel encoder which gives 1 count per pulse but does not give direction information.

2 = Incremental
1 = Quad x4 (default)

PPR FI2

Pulses Per Revolution FI2 (CP-266) is the number of pulses that are produced during one revolution of the encoder (or
motor or any other rotating part of your machine) that is connected to Frequency Input 2. This value is only used to
calculate RPM information for FI2 RPM (MP-04).

FI2 Pulses

Frequency Input 2 Pulses (CP-267) is used to scale the Frequency Input 2 in EU’s and EU/Tm. Enter the number of
pulses that corresponds to the number of EU’s that are entered in EU FI2 (CP-268).

EU FI2

EU Frequency Input 2 (CP-268) is used to scale the Frequency Input 2 in EU’s and EU/Tm. Enter the number of EU's
that corresponds to the number of pulses that are entered in FI2 Pulses (CP-267).

FbSyncPolarity

Feedback Sync Polarity (CP-269) is a selection that determines the polarity trigger direction of the Feedback Sync
pulses. The Feedback Sync input can be programmed to trigger on signals going from a low to high voltage level
(positive going) or from a high to low voltage level (negative going).

2 = Falling edge triggered (negative going)
1 = Rising edge triggered (positive going) (default)

Time Base

Time Base (CP-209) is the denominator, which represents the time (Tm) in the EU/Tm equation. The equation scales the
Frequency Inputs (FI1 and FI2) to EU/Tm.

3 = per Hour
2 = per Minute (default)
1 = per Second

FI2 Hz

Frequency Input 2 Hz (MP-03) displays the current frequency of the Frequency Input 2, in Hertz.

FI2 RPM

Frequency Input 2 RPM (MP-04) displays the current speed of the Frequency Input 2 encoder in RPM, based on PPR
FI2 (CP-266).

Fb EU/Tm

Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).

Fb Posn

Feedback Position (MP-20) displays the present value of the Feedback Position in Engineering Units, as specified by
Pulses FI2 (CP-267) and EU FI2 (CP-268). The placement of the decimal point is the same as the placement of the
decimal point in EU FI2 (CP-268).