C - 39

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

Minimum Value: 0

Maximum Value: 999999

Default Value: 0

Units: Ratio

CP-230 Direct SP

Direct Setpoint (CP-230) is active only in Direct Mode (CP202=0). It sends a voltage value directly to the Control
Output (CO_Sig) terminal. Run/Stop commands are recognized, but no other control function is active. All encoder
signals are ignored.

Minimum Value: -15.0

Maximum Value: 15

Default Value: 0.0

Units: Volts

CP-231 Acl Tm Drct

Acceleration Time Direct (CP-231) is the time, in seconds, that it takes to accelerate from 0 to the CO Max Volts (CP-271)
voltage, while operating in the Direct Mode.

Minimum Value: 0

Maximum Value: 3600

Default Value: 3.000

Units: Seconds

CP-232 Dcl Tm Drct

Deceleration Time Direct (CP-232) is the time, in seconds, that it takes to decelerate from the CO Max Volts (CP-271)
voltage to 0 volts, while operating in the Direct Mode.

Minimum Value: 0

Maximum Value: 3600

Default Value: 3.000

Units: Seconds

CP-240 Jog SP

Jog Setpoint (CP-240) is the speed, in EU/Tm, at which Jog ramps when it is activated. The Jog ramp rates are
referenced to this speed.

Minimum Value: 0

Maximum Value: 999999

Default Value: 200

Units: EU/Tm

CP-241 Acl Tm Jog

Acceleration Time Jog (CP-241) is the time, in seconds, to accelerate from 0 to the Jog SP (CP-240).

Minimum Value: 0.0

Maximum Value: 3600

Default Value: 1.000

Units: Seconds

CP-242 Acl Rt Jog

Acceleration Rate Jog (CP-242) is the rate, in EU/Tm per second, that it takes to accelerate when Jog is activated.