APPENDIX C: PARAMETER SUMMARY NUMERIC

QUICK REFERENCE

MP-01 FI1 Hz

Frequency Input 1 Hertz (MP-01) displays the current frequency of the Frequency Input 1, in Hertz.

Minimum Value: -180000

Maximum Value: 180000

Units: Hertz

MP-02 FI1 RPM

Frequency Input 1 RPM (MP-02) displays the current speed of the Frequency Input 1 encoder in RPM, based on PPR
FI1 (CP-261).

Minimum Value: -99999.9

Maximum Value: 99999.9

Units: RPM

MP-03 FI2 Hz

Frequency Input 2 Hz (MP-03) displays the current frequency of the Frequency Input 2, in Hertz.

Minimum Value: -180000

Maximum Value: 180000

Units: Hertz

MP-04 FI2 RPM

Frequency Input 2 RPM (MP-04) displays the current speed of the Frequency Input 2 encoder in RPM, based on PPR
FI2 (CP-266).

Minimum Value: -99999.9

Maximum Value: 99999.9

Units: RPM

MP-05 Ld EU/Tm

Frequency Input 1 Engineering Units per Time (MP-05) displays the current speed of the Frequency Input 1 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI1 (CP-262), EU FI1 (CP-263) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI1 (CP-263).

Minimum Value: -9999999

Maximum Value: 9999999

Units: EU/Tm

MP-06 Fb EU/Tm

Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).

Minimum Value: -9999999

Maximum Value: 9999999