Position counts p2/2 – CONTREX CX-1200 User Manual

Page 221

Advertising
background image

6 - 10

POSITION COUNTS P2/2

The Position Counts screen (page 2) allows you to select and monitor the position for the CX-1200. The first
line on the screen displays the current operating state.

State

State (MP-50) displays the present system operating state of the CX-1200 (see list below). Only one operating state
may be active at a time. To access either the “Run” or the “Jog” operating state, the F-Stop, R-Stop and H-Stop inputs
must be closed.

9 = Not Defined

8 = Diagnostics

7 = Not Defined

6 = Not Defined

5 = Jog

4 = Not Defined

3 = Run

2 = H-Stop

1 = R-Stop

0 = F-Stop

Run Mode

Run Mode (CP-202) sets the mode of operation and the subsequent Setpoint, that are used when your system is in
“Run”. The Setpoint and mode of operation combined, determine the Reference Speed and, if applicable, the Refer-
ence Position. The modes of operation are:

4 = Inv Foll Mode
3 = Follower Mode
2 = Master Mode (default)
1 = Direct Mode

ScaleFactor

Scale Factor (MP-41) displays the calculated ratio between the LdJbSzAve (MP-13) and the FbJbSzAve (MP-23). This
may be different than the scale factor actually being used by the control algorithm.

ActScaleFactor

Active Scale Factor (MP-42) displays the scale factor currently being utilized by the position control algorithm. The
ActScaleFactor (MP-42) may not be the same as ScaleFactor (MP-41).

LdPsnCnt

Lead Position Count (MP-180) displays Ld Posn (MP-10) in lines.

FbPsnCnt

Follower Position Count (MP-190) displays Fb Posn (MP-20) in lines.

PsnErrCnt

Position Error Count (MP-178) displays PosnErr (MP-33) in lines.

SyncFgDifC

Sync Flag Difference Count (MP-179) displays SyncFlgDif (MP-29) in lines.