CONTREX CX-1200 User Manual

Page 353

Advertising
background image

C - 7

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

MP-50 State

State (MP-50) displays the present system operating state of the CX-1200 (see list below). Only one operating state
may be active at a time. To access either the “Run” or the “Jog” operating state, the F-Stop, R-Stop and H-Stop inputs
must be closed.

9 = Not Defined
8 = Diagnostics
7 = Not Defined
6 = Not Defined
5 = Jog
4 = Not Defined
3 = Run
2 = H-Stop
1 = R-Stop
0 = F-Stop

Minimum Value: 0

Maximum Value: 9

Units: Coded

MP-51 Active Blk

Active Block (MP-51) displays the active block (0-7). The block can be selected and made active by the Block select bits
(Blk Sel A,B.C), in the PLC Programming screen if Blk Sel Source (CP-478) is set to “1” (DigIn & PLC). Or the block can
be selected and made active by the keypad if Blk Sel Source (CP-478) is set to “2” (Keypad Blk Sel).

Minimum Value: 0

Maximum Value: 7

Units: Coded

MP-52 InvalidBlks

Invalid Blocks (MP-52) displays the status of the blocks in the Block Setup screens. A “1” indicates that there is an
error with the corresponding block (see graphic below). Generally, this indicates that an overflow condition can occur if
the corresponding block is activated. In addition, since other parameters are used in conjunction with the Block
Parameters that you selected, an error can result from a parameter that is not selected in Block Parameters. If a bad block
is activated, the CX-1200 will execute an F-Stop until either the block error is corrected or a another block is activated.

Block 0

Block 1

Block 2

Block 3

Block 4

Block 5

Block 6

Block 7

Minimum Value: 00000000

Maximum Value: 11111111

Units: Coded