The equations used to scale the Auxiliary Analog output signal are given by:

MP-167 volts (or mA) = SS_AO * MP/CP (selected by CP-290) + SI_AO

written with parameter text:

AO Signal = SS_AO * MP/CP (selected by CP-290) + SI_AO

where

SS_AO = CP-294 - CP-292 volts (or mA) is the Scaling Slope

CP-295 - CP-293 in selected MP/CP units

written with parameter text:

SS_AO = AO RB - AO RA

A

Val@AO RB - Val@AO RA

SI_AO = CP-292 * CP-295 - CP-294 * CP-293 is the Scaling Intercept

CP-295 - CP-293

written with parameter text:

SI_AO = AO RA * Val@AO RB - AO RB * Val@AO RA

Val@AO RB - Val@AO RA

The AO is assumed calibrated so that the actual voltage (or current) is reflected by AO Signal (MP-167).