C - 72

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-453 Diag DAC Test

Diagnostic DAC Test (CP-453) selects and enables the type of output control that is used for the diagnostic Control
Output DAC test.

2 = Immediate Output
1 = Continuous Ramp
0 = Disabled (default)

Minimum Value: 0

Maximum Value: 2

Default Value: 0

Units: Coded

CP-454 Diag DAC Volts

Diagnostic DAC Volts (CP-454) is the maximum voltage output (either positive or negative) at the Control Output DAC
during a non zero diagnostic DAC test . The voltage corresponds to Diag DAC Bits (CP-455).

Minimum Value: -15

Maximum Value: 15

Default Value: 0

Units: Volts

CP-455 Diag DAC Bits

Diagnostic DAC Bits (CP-455) is the maximum value in bits written (either positive or negative) to the Control Output
DAC during a non zero diagnostic DAC test (CP-453) and when Diag En (CP-450) is set to “1” (On or enabled). The
value corresponds to Diag DAC Volts (CP-454).

Minimum Value: -32768

Maximum Value: 32767

Default Value: 0

Units: Bits

CP-456 Diag Rmp Tm

Diagnostic Ramp Time (CP-456) is the time, in seconds, from 0 volts to either positive or negative Diag DAC Volts (CP-
454) during a diagnostic DAC test with a ramp.

Minimum Value: 0

Maximum Value: 600

Default Value: 10.000

Units: Seconds

CP-460 Analog Cal En

Analog Calibration Enable (CP-456) enables the calibration process for the auxiliary analog board. When Analog Cal En
(CP-460) is set to “1” (On), the signal that is selected in Analog Cal Sel (CP-461) will be calibrated.

1 = Enabled
0 = Disabled (default)

Minimum Value: 0

Maximum Value: 1

Default Value: 0

Units: Coded