EDIT BLOCK PARMS

Block Parm 1 - Block Parm 16

The Edit Block Parms screens (pages 1-4) contain sixteen lines (Block Parm 1- 16) that allow you to assign sixteen
Control Parameters to Block Parms 1 through Block Parms 16 (CP-500 to CP-515). In turn, these Control Param-
eter assignments are reflected in corresponding lines in the Edit Blocks (0-7) screens (where the Control Param-
eter values are selected). When you enter a Parameter Code for a specific Control Parameter in a Block Parameter
line (Block Parm 1-16) , the parameter's name will appear immediately below that Block Parameter line. Enter a
“0” in the Block Parameter line(s) that you do not want to assigned Control Parameter. The line immediately
below will display “Not Used”. Master SP (CP-210) is the default Control Parameter that is assigned to Block Parm
1. You can not assign Monitor Parameters to Edit Block Params.

The graphic matrix below displays the interaction between the Edit Block Parms screens and the Edit Block 0-7
screens:

The assignment is reflected on the
corresponding value line in all eight
of the Edit Block screens —>

Parameter Values
will be entered in
the Edit Block (0-7)
screens

EDIT BLOCK 0

<Active Block>

5

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk0 Val 1

Blk0 Val 2

Blk0 Val 3

Blk0 Val 4

®NOT USED

®NOT USED

®Master SP

EDIT BLOCK 1

10

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk1 Val 1

Blk1 Val 2

Blk1 Val 3

Blk1 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 2

15

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk2 Val 1

Blk2 Val 2

Blk2 Val 3

Blk2 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 3

20

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk3 Val 1

Blk3 Val 2

Blk3 Val 3

Blk3 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 4

25

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk4 Val 1

Blk4 Val 2

Blk4 Val 3

Blk4 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 5

30

0

*

0

*

0

*

P1/4

®NOT USED

Blk5 Val 1

Blk5 Val 2

Blk5 Val 3

Blk5 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 6

35

0

*

0

*

0

*

P1/4

®NOT USED

Blk6 Val 1

Blk6 Val 2

Blk6 Val 3

Blk6 Val 4

®NOT USED

®NOT USED

->Master SP

EDIT BLOCK 7

40

0

*

0

*

0

*

P1/4

->NOT USED

Blk7 Val 1

Blk7 Val 2

Blk7 Val 3

Blk7 Val 4

->NOT USED

->NOT USED

->Master SP

<—

<—

<—

<—

<—

<—

<—

NOTE: In this example, the blocks are used to assign
eight different values to the Master Setpoint.
Master SP (CP-210) is assigned to the blocks
in the Edit Block Parms screen. Then the eight values
for Master Setpoint are assigned in the Edit Block
Screens. The block (0-7) that is active determines
which of the eight Master Setpoint values is used.

EDIT BLOCK PARMS

210

*

0

*

0

*

0

*

P1/4

->Master SP

->NOT USED

Block Parm 1

Block Parm 2

Block Parm 3

Block Parm 4

->NOT USED

->NOT USED

The assigned
Control
Parameter's
name appears
on the line
below —>

Assign (up to 16) Control Parameters
in the Edit Block Parms screens

<—

<—

<—

Advertising