A - 5

(Continued)

Appendix A: CX-1200 Specifications (continued)

Overall Dimensions:

19.6 cm (7.7 in) Bezel Height
10.2 cm (4.0 in) Bezel Width
17.8 cm (7.0 in) Total Depth

Panel Dimensions:

18.41 cm (7.25 in) Panel Height Cutout
9.27 cm (3.65 in) Panel Width Cutout
16.30 cm (6.30 in) Panel Inside Depth

Weight:

2.3 kilograms (5.1 Pounds)

Environmental

Operating Temperature:

0° to 55° C (32° to 131° F) Int. Enclosure
0° to 40° C (32° to 104° F) Ext. Enclosure

Storage Temperature:

-25° to 70° C (-13° to 158° F)

Environment:

The CX-1200 shall be installed in a pollution degree 2
macro-environment.

Relative Humidity:

0 to 95% Non-condensing

Altitude:

To 3,300 Feet (1000 Meters)

Performance

Setpoint Resolution:

6 Digits in Engineering Units

Speed Regulation:

0.01% Error in Lead Modes (>10Hz)
0.00% Error in Follower Modes (>10Hz)

Accel/Decel Ramps:

Settable in Time or Rate
0.1 to 3600.0 Seconds
0.001 to 999,999 EUs/T/Second
Separate for Run, Direct, Jog, H-Stop and R-Stop

Sync Rate:

20 Pulses per Second

Limits:

Maximum Speed
Minimum Speed
Trim Authority
Integral Limit

Alarms:

Zero Speed
Maximum Feedback
Maximum Accel/Decel
No Response
Programmable Custom Alms (6)