Danger – CONTREX CX-1200 User Manual

Page 309

Advertising
background image

8 - 12

DANGER

The CX-1200 should not be in “Run” or “Jog” when you
begin the diagnostics.

Changing the digital outputs may cause movement in
your system.

DIGITAL I/O TEST P1/1 continued

DO 7..0

Digital Output 7..0 (MP-102) displays the value of the “J2” digital outputs. A ‘1’ in the bit location indicates an active
“low voltage” condition on the corresponding open collector output (which would sink DC current). Refer to
Appendices: Appendix C for the DO 7..0 (MP-102) bit map list.

State

State (MP-50) displays the present system operating state of the CX-1200 (see list below). Only one operating state
may be active at a time. To access either the “Run” or the “Jog” operating state, the F-Stop, R-Stop and H-Stop inputs
must be closed.

9 = Not Defined

8 = Diagnostics

7 = Not Defined

6 = Not Defined

5 = Jog

4 = Not Defined

3 = Run

2 = H-Stop

1 = R-Stop

0 = F-Stop