Block parms editor – CONTREX CX-1200 User Manual

Page 166

Advertising
background image

5 - 73

P1/4

BLOCK PARMS EDITOR

210

*

0

*

0

*

0

*

Block Parm 1

->Line Spd SP

Block Parm 2

->NOT USED

Block Parm 3

->NOT USED

Block Parm 4

->NOT USED

Save Changes?
Press...
ENTER to Save
CLEAR to Discard

Press the Enter key to
save your changes or
press the Clear key to
discard your changes.

Edit Block Parms / Save

Press the Menu key from any of the Edit Block Parms screens to exit. If you have made changes in any
of the screens, a dialog box will pop up and give you the opportunity to either save or to discard your
changes.

If you have entered Control Parameters that can not be used in the blocks, then the code for each
Control Parameter that can not be used are highlighted, one by one, and the error message “Invalid
Parm” will flash five times in the error bar. Change all Control Parameter codes that are highlighted
and exit Edit Block Parms again. You can not save changes unless all fo the“Invalid Parm” codes
have been changed. Control Parameters that can be used are in the range of CP-202 through CP-206
and CP-209 through CP-249.

If you have entered a combination of 16 Control Parameters that create more internal variables than
the CX-1200 can execute, then the error message“Parm Mem Lmt” will flash twice in the error bar. Any
new Control Parameter codes that you entered will default back to “zero”. Although this scenario is
rare, it can occur. Either use different Control Parameters or use fewer Control Parameters.