Run monitor / system p1/3 – CONTREX CX-1200 User Manual

Page 217

Advertising
background image

6 - 6

RUN MONITOR / SYSTEM P1/3

The Run Monitor screen (page 1) contains monitor system data parameters. Setpoint X (CP-201) is also
included on this screen to allow convenient assess to your active setpoint.

State

State (MP-50) displays the present system operating state of the CX-1200 (see list below). Only one operating state
may be active at a time. To access either the “Run” or the “Jog” operating state, the F-Stop, R-Stop and H-Stop inputs
must be closed.

9 = Not Defined

8 = Diagnostics

7 = Not Defined

6 = Not Defined

5 = Jog

4 = Not Defined

3 = Run

2 = H-Stop

1 = R-Stop

0 = F-Stop

Setpoint X

Setpoint X (CP-201) displays the name and value of the setpoint that corresponds with the mode of operation selected
in RUN Mode (CP-202). The setpoint could be the Master SP (CP-210), the Follower SP (CP-220) or the Direct SP (CP-
230). Setpoint X acts as a quick access to the setpoint value. In addition to changing a setpoint value in the setpoint
screens, you can also change the value of the active setpoint by entering a new value in Setpoint X (CP-201).

Scaled Fb

Scaled Feedback (MP-40) displays the scaled feedback , which is scaled per ScFbDispEq (CP-250). The placement of
the decimal point is the same as the placement of the decimal point in Master SP (CP-210) in "Master" and Follower SP
(CP-220) in "Ratio or Inverse Ratio".

ActScaleFactor

Active Scale Factor (MP-42) displays the scale factor currently being utilized by the position control algorithm. The
ActScaleFactor (MP-42) may not be the same as ScaleFactor (MP-41).

Ld EU/Tm

Frequency Input 1 Engineering Units per Time (MP-05) displays the current speed of the Frequency Input 1 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI1 (CP-262), EU FI1 (CP-263) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI1 (CP-263).

Fb EU/Tm

Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).

Ld Posn

Lead Position (MP-10) displays the present value of the Lead Position in Engineering Units, as specified by Pulses
FI1 (CP-262) and EU FI1 (CP-263). The placement of the decimal point is the same as the placement of the decimal point
in EU FI1 (CP-263).

Fb Posn

Feedback Position (MP-20) displays the present value of the Feedback Position in Engineering Units, as specified by
Pulses FI2 (CP-267) and EU FI2 (CP-268). The placement of the decimal point is the same as the placement of the
decimal point in EU FI2 (CP-268).

PosnErr

Position Error (MP-33) displays the value, in engineering units, of the accumulated position error between the lead
(FI1) and the feedback (FI2) input signals. The placement of the decimal point is the same as the placement of the
decimal point in EU FI2 (CP-268).